Skip to Content

Hikvision ELG-150-48A Industrial Power Supply 48V 150W, IP65, -40 to +90°C

  • 150W single output power supply for industrial PoE switch
  • Input: 100-305 VAC/142-431 VDC
  • Output: 48 VDC, 3.13 A
  • IP65 rating protection
  • Wide operating temperature: -40℃ to +90℃ for outdoor use.
Price
⃁ 240.00 ⃁ 240.00 ⃁ 300.00
(Tax excluded)
  • Delivery within 2–5 business days across Saudi Arabia
  • Warranty according to the manufacturer
  • Tax invoice with every order
  • Technical support before and after purchase

Not sure this model fits your setup? Read the buying guide

Overview of Hikvision ELG-150-48A

The Hikvision ELG-150-48A is a 150W single-output industrial power supply for industrial PoE switches, providing 48 VDC at 3.13 A from a wide 100-305 VAC or 142-431 VDC input. It features an adjustable output via built-in potentiometer, typical 90% efficiency, IP65 protection and a -40 to +90 °C case temperature range, with over-current, short-circuit, over-voltage and over-temperature protection. It is listed for use with the DS-3T0506P and DS-3T0510P industrial switches, making it suitable for outdoor poles and cabinets at Saudi parking areas, perimeter fences, farms and industrial sites.

Technical Specifications – Hikvision ELG-150-48A

OUTPUT

DC VOLTAGE48V
CONSTANT CURRENT REGIONNote.224~48V
RATED CURRENT(ForBETypeonly)2.8A
RATED POWER100VAC~180VAC (ForAlltheTypes) 105W 200VAC~305VAC (ExceptforBEType) 150.2W (ForBETypeonly) 134.4W
RIPPLE & NOISE (Max.) Note.3250mVp-p
VOLTAGE ADJ. RANGEAdjustableforA/AB-Typeonly(viathebuilt-inpotentiometer) 43.2~52.8V
CURRENT ADJ. RANGEAdjustableforA/AB-Typeonly(viathebuilt-inpotentiometer) 1.56~3.13A
VOLTAGE TOLERANCE Note.4±2.0%
LINE REGULATION±0.5%
LOAD REGULATION±0.5%
AUXILIARY DC OUTPUTNominal15V(deviation11.5~15.5V)@0.3AforBE-Typeonly
SETUP, RISE TIME Note.61600ms, 80ms/115VAC 500ms,100ms/230VAC
HOLD UP TIME (Typ.)10ms/115VAC, 230VAC
RATEDCURRENT3.13A

INPUT

VOLTAGE RANGE Note.5100~ 305VAC 142~431VDC (Please refer to STATIC CHARACTERISTIC\" section)"
FREQUENCY RANGE47~63Hz
POWER FACTORPF≧0.97/115 VAC, PF≧0.95/230 VAC, PF≧0.92/277 VAC@full load (Please refer to POWER FACTOR(PF) CHARACTERISTIC\" section)"
TOTAL HARMONIC DISTORTIONTHD<20%(@load≧50%/115 VC; @load≧60%/230 VAC; @load≧75%/277 VAC) (Please refer to“TOTAL HARMONIC DISTORTION(THD)”section)
EFFICIENCY (Typ.)90%
EFFICIENCY (Typ.)(ForBETypeonly)88%
AC CURRENT1.7 A/115 VAC 0.9 A/230 VAC 0.7 A/277 VAC
INRUSH CURRENT (Typ.)COLD START 65 A(twidth=550 μ s measured at 50% Ipeak) at 230 VAC ; Per NEMA 410
MAX .No. Of PSUs On 16A CIRCUIT BREAKER3 units (circuit breaker of type B)/ 6 units (circuit breaker of type C) at 230 VAC
LEAKAGE CURRENT<0.75 mA/277 VAC
NO LOAD / STANDBY POWER CONSUMPTIONNo load power consumption<0.5W for Blank/A/Dx/D2-Type Standby power consumption <0.5W for B/AB/DA-Type

PROTECTION

OVER CURRENT95~108% Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUITHiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE54~62V Shut down output voltage, re-power on to recover
OVER TEMPERATUREShut down output voltage, re-power on to recover

ENVIRONMENT

WORKING TEMP.Tcase=-40~+90℃ (Please refer to“ OUTPUT LOAD vs TEMPERATURE”section)
MAX. CASE TEMP.Tcase=+90℃
WORKING HUMIDITY20~95% RH non-condensing
STORAGE TEMP., HUMIDITY-40~+80℃, 10~95% RH
TEMP. COEFFICIENT±0.03%/℃ (0~60℃)
VIBRATION10~500 Hz, 5G 12min./1cycle, period for 72min. each along X,Y,Z axes

SAFETY& EMC

SAFETY STANDARDSUL8750(type”HL”)(except for BE-type),CSA C22.2 No. 250.13-12; IEC/EN/AS/NZS 61347-1,IEC/EN/AS/NZS 61347-2-13 independent, EN62384,BIS IS15885(for 12/12B/12DA/24/24B/24DA/36A/42/42A/48A/54 only), EAC TP TC 004,GB19510.1, GB19510.14; IP65 or IP67; KC61347-1, KC61347-2-13 approved
DALI STANDARDSCompliance to IEC62386-101,102,207 for DA-Type only
WITHSTAND VOLTAGEI/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms/ 500VDC / 25℃/ 70%RH
EMC EMISSIONCompliance to EN55015, EN61000-3-2 ClassC(@load ≧ 60%); EN61000-3-3; GB17743 , GB17625.1 , EAC TPTC020 ; KCKN15 ,KN61547
EMC IMMUNITYCompliance to EN61000-4-2,3,4,5,6,8,11 ; EN61547 , light industry level (surge immunity Line-Earth 6KV, Line-Line 4KV),EAC TP TC020 ; KC KN 15,KN 61547

OTHERS

MTBF899.8K hrs min. Telcordia SR-332 (Bellcore) 313.66 Khrs min.MIL-HDBK-217F(25℃)
DIMENSION219*63-35.5mm (L*W*H)
PACKING0.95Kg ; 16pcs/16.0kg/0.77CUFT

Source: Hikvision official website. Specifications are subject to change by the manufacturer.